Fluke 750P Series Pressure Modules will turn your Fluke multifunction
calibrator into a full-fledged pressure calibrator. These flexible
modules not only work with multifunction calibrators like the 725, 726
or 750 Series Calibrators but also extend the measurement range of
Fluke pressure calibrators. Since the pressure modules are calibrated
independently, they can be swapped from one calibrator to another
without a loss of accuracy or traceability.
Measuring pressure with Fluke 750P Series Pressure modules is as easy
as connecting the module to a pressure source or hand pump, connecting
the pressure module cable to the calibrator and then applying pressure
from the pressure source. At the touch of a button the measured
pressure is displayed digitally on the calibrator in up to 11 different
engineering units quickly giving you the data you need. And, with "no
tools required" connectors you don't even need to reach for a wrench to
make connections.
When used with the 750 Series Documenting Process Calibrators pressure
readings can even be date/time stamped and stored in documented
calibration records for later retrieval. This saves time, eliminates
errors, and supports compliance with quality standards and regulations.
With over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.
Choose from:
With more than 50 pressure modules to choose from, some of the more popular modules include:
Click the Models tab above for a full list of pressure modules.
Designed to go where you workPressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there's no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.
Differential Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750P00 | 0 to 1 inH2O (0 to 2.5 mBar) | 30X | Dry air | Dry air | |
750P3IN | 0 to 3 Inch H2O (0 to 7.5 mbar) | 10X | Dry air | Dry air | |
750P5IN | 0 to 5 Inch H2O (0 to 12.5 mbar) | 6X | Dry air | Dry air | |
750P017 | 0 to 10 inH2O (0 to 25 mBar) | 3X | Dry air | Dry air | |
750P02 | 0 to 1 psi (0 to 70 mBar) | 3X | Dry air | Dry air | |
750P22 | 0 to 1 psi (0 to 70 mBar) | 3X | 316 SS | Dry air | |
750P03 | 0 to 5 psi (0 to 350 mBar) | 3X | Dry air | Dry air | |
750P23 | 0 to 5 psi (0 to 350 mBar) | 4X | 316 SS | Dry air | |
750P04 | 0 to 15 psi (0 to 1 bar) | 3X | Dry air | Dry air | |
750P247 | 0 to 15 psi (0 to 1 bar) | 4X | 316 SS | Dry air | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750P00 | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
750P3IN | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
750P5IN | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
750P017 | ±0.1% | ±0.2% | ±0.3% | ±0.15% | ±0.25% |
750P02 | ±0.050% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
750P22 | ±0.050% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
750P03 | ±0.02% | ±0.04% | ±0.05% | ±0.035% | ±0.04% |
750P23 | ±0.02% | ±0.04% | ±0.05% | ±0.035% | ±0.04% |
750P04 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P247 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
Gage Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750P057 | 0 to 30 psi (0 to 2 bar) | 4X | 316 SS | N/A | |
750P067 | 0 to 100 psi (0 to 7 bar) | 4X | 316 SS | N/A | |
750P277 | 0 to 300 psi (0 to 20 bar) | 4X | 316 SS | N/A | |
750P07 | 0 to 500 psi (0 to 35 bar) | 4X | 316 SS | N/A | |
750P08 | 0 to 1000 psi (0 to 70 bar) | 3X | 316 SS | N/A | |
750P097 | 0 to 1500 psi (0 to 100 bar) | 3X | 316 SS | N/A | |
750P2000 | 0 to 2000 psi (0 to 140 bar) | 3X | 316 SS | N/A | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750P057 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P067 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P277 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P07 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P08 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P097 | ±0.0175% | ±0.035% | ± 0.045% | ±0.03% | ±0.04% |
750P2000 | ±0.0175% | ±0.035% | ± 0.045% | ±0.03% | ±0.04% |
High Pressure Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750P29 | 0 to 3000 psi (0 to 200 bar) | 3X | 316 SS | N/A | |
750P30 | 0 to 5000 psi (0 to 340 bar) | 3X | 316 SS | N/A | |
750P31 | 0 to 10000 psi (0 to 700 bar) | 2X | 316 SS | N/A | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750P29 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P30 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P31 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
Absolute Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750PA3 | 0 to 5 psia (0 to 350 mBar) | 4X | 316 SS | N/A | |
750PA47 | 0 to 15 psia (0 to 1 bar) | 4X | 316 SS | N/A | |
750PA5 | 0 to 30 psia (0 to 2 bar) | 4X | 316 SS | N/A | |
750PA6 | 0 to 100 psia (0 to 7 bar) | 4X | 316 SS | N/A | |
750PA27 | 0 to 300 psia (0 to 20 bar) | 4X | 316 SS | N/A | |
750PA7 | 0 to 500 psia (0 to 35 bar) | 4X | 316 SS | N/A | |
750PA8 | 0 to 1000 psia (0 to 70 bar) | 3X | 316 SS | N/A | |
750PA9 | 0 to 1500 psia (0 to 100 bar) | 3X | 316 SS | N/A | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750PA3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA47 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA5 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA6 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA27 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA7 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA8 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA9 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
Vacuum Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750PV3 | -5 psi (-350 mBar) | 4X | 316 SS | Dry air | |
750PV4 | -15 psi (-1 bar) | 4X | 316 SS | Dry air | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750PV3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PV4 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
Dual Range Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750PD2 | -1 to 1 psi (-70 to 70 mBar) | 4X | 316 SS | Dry air | |
750PD3 | -5 to 5 psi (-350 to 350 mBar) | 4X | 316 SS | Dry air | |
750PD10 | -10 to 10 psi (-700 to 700 mBar) | 4X | 316 SS | Dry air | |
750PD4 | -15 to 15 psi (-1 to 1 bar) | 4X | 316 SS | Dry air | |
750PD5 | -15 to 30 psi (-1 to 2 bar) | 4X | 316 SS | - | |
750PD50 | -15 to 50 psi (-1 to 3.5 bar) | 4X | 316 SS | - | |
750PD6 | -15 to 100 psi (-1 to 7 bar) | 4X | 316 SS | - | |
750PD7 | -15 to 200 psi (-1 to 14 bar) | 4X | 316 SS | - | |
750PD27 | -15 to 300 psi (-1 to 20 bar) | 4X | 316 SS | - | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750PD2 | ±0.05% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
750PD3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PD10 | ±0.025% | ±0.05% | ±0.07% | ±0.04% | ±0.06% |
750PD4 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ± 0.04% |
750PD5 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD50 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD6 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD7 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD27 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
Reference Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750R045 | 0 to 15 psi (0 to 1 bar) | 3X | Dry air | Dry air | |
750R065 | 0 to 100 psi (0 to 7 bar) | 4X | 316 SS | - | |
750R27 | 0 to 300 psi (0 to 20 bar) | 4X | 316 SS | - | |
750R07 | 0 to 500 psi (0 to 35 bar) | 4X | 316 SS | - | |
750R085 | 0 to 1000 psi (0 to 70 bar) | 3X | 316 SS | - | |
750R29 | 0 to 3000 psi (0 to 200 bar) | 3X | 316 SS | - | |
750R30 | 0 to 5000 psi (0 to 340 bar) | 3X | 316 SS | - | |
750R315 | 0 to 10000 psi (0 to 700 bar) | 2X | 316 SS | - | |
750RD5 | -15 to 30 psi (-1 to 2 bar) | 4X | Dry air | - | |
750RD65 | -12 to 100 psi (-0.8 to 7 bar) | 4X | 316 SS | - | |
750RD27 | -12 to 300 psi (-0.8 to 20 bar) | 4X | 316 SS | - | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
750R045 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R065 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R27 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R07 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R085 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R29 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R30 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R315 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750RD5 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750RD65 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750RD27 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
1. Total uncertainty, % of full span
for temperature range 0°C to +50°C, one year interval. Total
uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one
year interval. No 6 month specification available for range -10°C to
0°C. 2. "Non-corrosive gasses" indicates Dry air or non-corrosive gas as compatible media. "Stainless Steel 316-SS" indicates media compatible with Type 316 Stainless Steel. 3. Specifications % of Full Span unless otherwise noted. 4. Reference Uncertainty is the specification for as left data for 24 hours. 5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification. 6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure. 7. Intrinsically Safe pressure module available in this pressure range. |
These cookies ensure that the webstore functions properly. Think of keeping track of your language and your products in your shopping basket, log on with your account, the checkout form, filter search results etc.
We use analytical and tracking cookies to see how we can improve the webstore and how we can adapt content and potential advertisements to your preference.